Q : I like to know the range (time base) length and sensitivity of MsSR-2020.
 A : The test result for 6.35-mm-thick, carbon-steel plate, performed at Southwest Research
      Institute in San Antonio, Texas, USA, showed that a 13-mm-long, 50-percent-thickness-
      deep notch can be detected over about 6-meter range with signal-to-noise ratio of 2 by
      using 80-kHz shear-horizontal wave(SH wave, velocity ~ 3260 m/sec).
      The wave was generated with 8-inch-long probe.
      For inspection of 5-mm-long, austenitic stainless steel (non-ferromagnetic material),
      the SH wave would be generated by using a thin nickel bonded on the surface.
      Using the thin nickel for the generation of SH wave, the MsSR-2020 will have significantly
      improved performance.